Shakmat Modular Triple Steeple

¥49,900 (Tax excluded ¥45,364)
Compact envelope generator with 5 modes and 3 independently controllable channels

Format: Eurorack
Width: 8HP
Depth: 21mm
Current: 40mA @ + 12V, 8mA @ -12V

Manual PDF (English)

In stock. Orders made by 15:XNUMX will be shipped the same day

MUSICAL FEATURES

Triple Steeple is a 3-channel envelope generator with time and symmetry controls. Control anything from basic envelope shapes to complex modulations with Triple Steeple's 5 envelope modes, linear or exponential response, CV control over time, assignable CV input, and internal normalization You can create signals.

  • Dedicated time and symmetry controls for each of the three envelope generators
  • Five modes: trigger response, gate response, loop, gated loop, and clocked loop
  • linear or exponential response
  • Configurable envelope level
  • 2.5ms to 15s timing (minimum attack or decay time is 250us)
  • VCA mode or accent mode available with assignable CV inputs
  • Input/output normalization
  • Settings save function
  • Thin design

HOW TO USE

time and symmetry

Triple Steeple offers time and symmetry control for each envelope rather than the classic attack-decay approach.

Set via Time knob and CV inputTeamThe parameter is the sum of Attack Time and Decay Time.Manipulating this parameter will change both attack and decay times by the same amount.

SymmetryThe parameter defines the ratio of attack time to decay time via the Symmetry knob.When this knob is at minimum, the envelope has zero attack time and only decay.Turning the knob clockwise increases the attack time while decreasing the decay time. With the Symmetry knob set to the middle position, the envelope is symmetrical, i.e. the attack and decay times are identical.With the knob fully clockwise, the envelope behaves in attack only, with no decay.


5 modes

Each envelope features 5 different modes.to change the mode, for the corresponding channelFashionClick the button.The selected mode is indicated by two LEDs.

01.Triggered
A rising edge triggers a one-cycle envelope.


02.Gated
By inputting the gate signal, it generates an ASR (Attack-Sustain-Release) type envelope.


03.Looped
The envelope loops continuously.The envelope is reset when a rising edge is input.


04.Gated Loop
The envelope loops continuously while the input signal, Gate, is high.If the incoming gate signal disappears, it immediately returns to the minimum value.


05.Clocked Loop
The envelope cycles according to the frequency of the incoming clock.In this mode Time acts like the number of divisions parameter.The number of divisions available are 1, 2, 3, 4, 5, 6, 7, and 8, with values ​​increasing as the knob is turned to the right.


Envelope shape

Triple Steeple allows you to choose between linear (linear/default) or exponential (exponential) shape for each envelope.To switch to exponential response,FashionPress and hold the button for 2 seconds (white EXP LED lights up).


ACV input and Level menu

To enter the CV input assignment menu,ACV/LVLClick the button once and verify that the button lights up.This willACVInput assignments are now editable, allowing you to control symmetry or amplitude for any of the three channels.

To switch the assignment of a specific channel, click the corresponding channel'sFashionClick the button. The two Mode and Shape LEDs indicate the selected mode as follows.

01.Symmetry
The ACV input acts as a symmetrical bipolar control (-5V to +5V) and adds to the channel's Symmetry parameter value.


02.Amplitude
The ACV input functions as a positive unipolar control of amplitude (0V to +0V), varying between the amplitude value selected in the Level menu and 5V.This option has no effect if the selected Level is 0V.


03.Accent
While the ACV input is gated high, the amplitude of the envelope rises from the set Level to 8V.This option only works if the channel's Level is set to something other than 8V.


Any parameter can be assigned simultaneously to one of the three channels.

LevelTo enter the settings menu ofACV/LVLClick the button again (button flashes).This allows you to edit the amplitude level width of the envelope.

To exit the menu and return to normal mode selection operation,ACV/LVLClick the button again.


Input normalization

Channels 2 and 3 receive the state of the previous channel's decay in the absence of patches to their respective gate inputs.In the image below, you can see how this normalization allows channel 1's decay in Gate mode to act as a gate for channel 2.

Output normalization

Output 3 will output the maximum value of the previous two channel outputs unless normalization is disabled by patching the cable.

Patching a cable to output 1 or 2 will exclude that channel's envelope from the 'MAX' function.

In this example, you can see that there is no patch to the output jacks of channels 1 and 2, and that the output of channel 3 is outputting the maximum value of all 3 channels.


save the current state

To save the currently selected mode, envelope response type, amplitude level, and ACV assignment, ACVHold the button for 2 seconds.All LEDs will flash to indicate the save is complete.