4ms Rotating Clock Divider ( RCD )
Format: Eurorack
Width: 4HP
Depth: 35mm
Current: 19mA @ + 12V, 4mA @ -12V, 14mA @ + 5V
(5mA @ + 33V, 12mA @ -4V when making + 12V inside RCD by jumper setting)
Manual pdf (English)
Format: Eurorack
Width: 4HP
Depth: 35mm
Current: 19mA @ + 12V, 4mA @ -12V, 14mA @ + 5V
(5mA @ + 33V, 12mA @ -4V when making + 12V inside RCD by jumper setting)
Manual pdf (English)
The 6 blue jumpers on the upper right are the jumpers set on the RCD. The image is the default setting for jumpers. In RCD Breakout, this jumper part points to the cable from RCDBO, and you can change these settings on the panel.
Jumper settings for Nos. 3,4,5, 3,4 and 8. The combination of numbers 3,4 and XNUMX determines the basic range of the clock signal output from the XNUMX outputs. Also, the range of the number of divisions that can be moved by Rotation CV is determined by numbers XNUMX and XNUMX (Total Rotatable Divide-by Range).
No. 5 is a jumper to set "Spread Mode". When it is On, it outputs from 8 outputs relatively evenly from a clock with a small division number to a clock with a large division number, but when it is Off, it is the maximum as shown in the table above. Only clocks that are close to the number of divisions of are output from the eight outputs.
6th jumper setting. When set to ON, the length will be reset according to the Divide-by Range determined by the 3,4rd and XNUMXth jumpers.
No. 7 jumper setting. Down-beat is a mode in which the clock of any division number starts with "ON" at the first beat. Up-beat is a mode in which the clock starts with "ON" at the last beat of each division number.
8th jumper setting. If you select On, the gate signal will be kept on for half the time from when the output signal is turned on until the next ON timing. When set to Off, the output signal triggers and turns on only for a very short time.